Technical Principles and Innovative Values​

Innovation Point 1:Industrial-Grade Memory with Long-Term Data Retention​

The SCHNEIDER TSXPBY10 uses industrial-grade CMOS RAM paired with a high-capacity lithium battery,ensuring data retention for up to 10 years—even during prolonged power outages.Unlike consumer-grade memory modules that lose data within hours without power,this design eliminates the risk of critical control program or process data loss in remote or unstable power environments.A mining operation in Australia used this feature to maintain PLC program integrity during 48-hour power outages,avoiding$50,000 in production losses per outage.​

Innovation Point 2:Seamless Modicon Quantum Integration​

The SCHNEIDER TSXPBY10 is engineered to plug directly into the Modicon Quantum PLC backplane,requiring no additional wiring or configuration tools.The PLC automatically detects the module and integrates the 10MB RAM into its memory map within seconds of power-up.This plug-and-play functionality reduces installation time by 80%compared to third-party memory modules,which often require complex software configuration.A food processing plant installed 5 SCHNEIDER TSXPBY10 modules across its PLC network in less than 1 hour,minimizing production disruption.​

Innovation Point 3:High-Speed Data Access for Complex Control​

With a 100ns access speed,the SCHNEIDER TSXPBY10 enables fast execution of complex control programs—such as multi-loop PID control,sequential logic,and data logging.Unlike slower memory modules that cause program execution delays(leading to process instability),this high-speed performance ensures the PLC can handle up to 50%more control tasks without latency.A chemical plant using the module reported a 25%reduction in process variability after expanding its PLC memory,as the controller could now run advanced predictive maintenance algorithms in real time.​

Application Cases and Industry Value​

Case 1:Chemical Plant Process Control​

A large chemical plant in Germany operated 10 Modicon Quantum PLCs to control its batch reaction processes.Each PLC’s built-in 2MB memory was insufficient to store the updated batch control program(which included detailed recipe management and safety联锁logic).The plant was forced to use external memory cards,which caused program loading delays and occasional data corruption.After installing the SCHNEIDER TSXPBY10 in each PLC,the memory capacity expanded to 12MB,enabling full program storage and eliminating external memory dependencies.The module’s high-speed access reduced batch cycle time by 15%(from 4 hours to 3.4 hours),and the battery backup prevented recipe data loss during 2 power outages.Over 1 year,the plant increased batch production by 18%and saved$120,000 in downtime costs.​

Case 2:Power Plant Auxiliary Systems​

A coal-fired power plant in the United States used Modicon Quantum PLCs to control its auxiliary systems(cooling water,fuel handling,and ash removal).The PLCs’limited memory prevented the integration of real-time performance monitoring software,requiring manual data logging and increasing maintenance response time.By adding the SCHNEIDER TSXPBY10 module,the plant expanded each PLC’s memory to support the monitoring software,enabling real-time tracking of equipment temperatures,pressures,and vibration levels.The module’s data retention feature ensured no monitoring data was lost during transient power fluctuations.Within 3 months,the plant reduced unplanned maintenance by 30%and extended equipment lifespan by 2 years,resulting in$90,000 in annual savings.​

Related Product Combination Solutions​

SCHNEIDER 140CPU11303:Modicon Quantum CPU module—paired with SCHNEIDER TSXPBY10 to provide core control and expanded memory for small-to-medium automation systems.​

SCHNEIDER TSXCF032:Flash memory module—complementary to SCHNEIDER TSXPBY10 for non-volatile program storage(e.g.,backup of critical control logic).​

SCHNEIDER TSXPSY1600:Power supply module—provides stable 5V DC power to SCHNEIDER TSXPBY10 and other Modicon Quantum modules.​

SCHNEIDER 140ARI03010:Analog input module—works with SCHNEIDER TSXPBY10-equipped PLCs to collect process data(e.g.,temperature,pressure)for storage and analysis.​

SCHNEIDER SoMachine Software:PLC programming tool—used to configure and manage memory allocation for SCHNEIDER TSXPBY10 in Modicon Quantum systems.​

SCHNEIDER TSXCTY2A:Counter module—integrates with SCHNEIDER TSXPBY10-expanded PLCs for high-speed counting applications(e.g.,production line part tracking).​

SCHNEIDER 140XTS00200:Communication module—enables SCHNEIDER TSXPBY10-equipped PLCs to transmit stored data to SCADA systems(e.g.,process trending,alarm logging).​

Installation,Maintenance,and Full-Cycle Support​

Installation Preparation:Before installing the SCHNEIDER TSXPBY10,ensure the Modicon Quantum PLC is powered off and the cabinet environment meets temperature(0°C~60°C)and humidity(5%~95%non-condensing)requirements.Locate an empty slot in the PLC backplane(compatible with Modicon Quantum rack units)and align the module’s connectors with the backplane pins.Gently push the module into the slot until it clicks into place—no tools are required for installation.Power on the PLC and verify the module is detected via the PLC’s diagnostic interface(e.g.,using SoMachine Software)to confirm successful integration.​

Maintenance and Fault Handling:Routine maintenance for the SCHNEIDER TSXPBY10 focuses on battery replacement and memory health checks.The internal lithium battery should be replaced every 5 years(or when the PLC diagnostic system alerts to low battery voltage)to ensure data retention.Use only Schneider-approved replacement batteries(part number TSXBY10BAT)to avoid compatibility issues.Monthly checks include verifying the module’s status LED(solid green=normal operation,flashing red=fault)and running a memory integrity test via SoMachine Software.If a fault occurs(e.g.,memory corruption),the PLC will generate a diagnostic code—common issues like loose connections can be resolved by reseating the module,while memory errors may require restoring the program from backup.​

Full-Cycle Support:We offer a 36-month warranty for the SCHNEIDER TSXPBY10,covering manufacturing defects and performance issues.Our global technical support team provides 24/7 assistance—including remote guidance for installation,troubleshooting of integration issues,and advice on memory optimization.For critical applications(e.g.,power plants,chemical processing),we offer on-site services to verify module performance and train maintenance staff on battery replacement and data backup procedures.Extended warranty and battery replacement plans are available to extend the module’s 10-year typical lifespan,ensuring long-term reliability in industrial environments.​

Ready to expand your Modicon Quantum PLC’s memory and enhance automation performance with the SCHNEIDER TSXPBY10?Contact us today to discuss your application needs—whether in manufacturing,process control,or infrastructure—and receive a customized solution tailored to your industry and operational goals!

选择深圳长欣,选择放心,售后无忧 大量现货,当天顺丰发货!!!